Cranking Problems

 

Do the following to set up for unit test.

 

     1. It is very important that the magnetic pickup is installed

         in the bell housing and properly adjusted.

     2. Put  voltage on 13 and check to see that you have

         2 to 15 volts AC on terminals 1 and 2.

     3. If you don’t have the  voltage in step 2 while the engine

         is cranking then you must check and adjust magnetic

         pickup. It may be dirty or have a broken wire.

     4. If your engine isn’t cranking at all check to see if you

         have voltage on terminal 6 when you put voltage to

         terminal 13.

     5. If nothing is working then do the basic engine test.

          After you have done that come back to step 6.

     6. Now that you have confirmed engine control operation

         be sure you adjust the unit as shown in adjustments

     7. If you are getting one second cranks despite your

         current crank time setting be sure sw 5 is off

     8. Be sure crank disconnect is not set to zero

     9. If you never have seen voltage on term. 6 you should

         call 317-849-8470 and ask for sales/service and we

         will assist you further

 

     Remember this is just for testing. YOU must reset the

     control by using the Adjustments guide accessable from

     you main engine control page.

 

 

 

    

 

 

 

 

 

 

 

 

 

Copyright 2003 Engineering Concepts Unlimited Inc.